Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Rev chil anest ; 48(1): 62-67, 2019. ilus
Article in Spanish | LILACS | ID: biblio-1451551

ABSTRACT

9-year-old patient diagnosed with scimitar syndrome through transthoracic echocardiogram and cardiac catheterization. Surgical correction is performed by anastomosing the collector of the pulmonary right vein to AI through the interatrial septum, tunneling it with a pericardic patch. The study findings and echocardiographic images of such surgical repair and the spectrum of pulsed Doppler differentiating between right and left pulmonary veins will be shown below. The connection through the septum was evidenced, simulating an interatrial communication. A difference was found among the measured points S, D, A and between the left and right pulmonary veins, without this resulting in a stenosis during the repair.


Paciente de 9 años de edad el cual es diagnosticado con síndrome de cimitarra a través de ecografía transtorácica y cateterismo cardiaco. Se realiza cirugía correctora la cual se anastomosa el colector de vena pulmonar derecha hacia AI a través del septum interauricular, tunelizándolo con parche pericárdico. A continuación se muestran los hallazgos e imágenes ecocardiográficas de tal reparación y el espectro doppler pulsado diferenciado entre las venas pulmonares derechas e izquierdas. Se pudo evidenciar la conexión a través del septum, simulando una comunicación interauricular. Se halló una diferencia entre los puntos medidos S, D, A entre las venas pulmonares izquierdas y derechas, sin que esto significara una estenosis en la reparación.


Subject(s)
Humans , Male , Child , Scimitar Syndrome/surgery , Scimitar Syndrome/diagnostic imaging , Echocardiography, Transesophageal , Cardiac Catheterization
2.
Anest. analg. reanim ; 31(2): 5-14, dic. 2018. tab, graf
Article in Spanish | LILACS | ID: biblio-983763

ABSTRACT

RESUMEN: En la práctica diaria uno de los eventos que más se presenta es la hipotensión luego de la salida de circulación extracorpórea (CEC). La posibilidad de contar con ecocardiografía a partir del 2015 en el nosocomio ha ayudado a orientar al anestesiólogo sobre el estado hemodinámico, sin embargo, no se ha podido esclarecer la causa de esta hipotensión utilizando esta herramienta. El objetivo de este estudio es hallar los parámetros ecocardiográficos que más se relacionan con la hipotensión refractaria luego de la salida de la (CEC). Se seleccionaron pacientes sometidos a cirugías de comunicación interauricular e interventricular monitorizados con ecocardiografía transesofágica. La muestra se estratificó en dos grupos, hipotensos (casos) y normotensos (controles) luego de la salida de CEC. Estudio observacional, de casos y controles, retrospectivo. En el análisis del total de pacientes se encontraron diferencias estadísticamente significativas (p<0.05) de los parámetros ecocardiográficos indicadores de hipovolemia entre los grupos. No hubo diferencias estadísticas (p=0.083) en los parámetros ecocardiográficos de contractilidad. Los resultados obtenidos demostraron que los parámetros ecográficos de hipovolemia fueron los que más se asociaron al momento de la hipotensión. Esto permite orientar al profesional a un uso racional de drogas inotrópicas y reposición de volumen.


SUMMARY: In daily practice, one of the most frequent events is hypotension after the of extracorporeal circulation (ECC). The possibility of having an echocardiography from 2015 has been a guiding means in the hemodynamic state, however, the cause of this hypotension has not been clarified. The aim of this study is to find the echocardiographic parameters that are most related to refractory hypotension after ECC. Patients undergoing atrial and interventricular communication surgeries monitored with transesophageal echocardiography were selected. The sample was stratified into two groups, hypotensive (cases) and normotensive (controls) after ECC. Observational, case-control study, retrospective. In the analysis of the total of the patients, were found statistically significant differences (p <0.05) in the echocardiographic parameters indicating hypovolemia between the groups. There were no differences in the statistics (p = 0.83) in the echocardiographic parameters of contractility. The results showed that the ultrasonographic parameters of hypovolemia were those associated with hypotension. This allows the professional to be guided to a rational use of inotropic drugs and volume replacement.


RESUMO: Na prática diária, um dos eventos mais frequentes é a hipotensão após a saída da circulação extracorpórea (CEC). A possibilidade de ter ecocardiografia a partir de 2015 no hospital ajudou a orientar o anestesista sobre o estado hemodinâmico, no entanto, não foi capaz de esclarecer a causa desta hipotensão usando esta ferramenta. O objetivo deste estudo é encontrar os parâmetros ecocardiográficos mais relacionados à hipotensão refratária após a saída da artéria coronária (CEC). Pacientes submetidos a cirurgias de comunicação atrial e interventricular monitoradas por ecocardiograma transesofágico foram selecionados. A amostra foi estratificada em dois grupos, hipotensivos (casos) e normotensos (controles) após a saída do CEC. Estudo observacional, caso-controle, retrospectivo. Na análise do número total de pacientes, foram encontradas diferenças estatisticamente significantes (p <0,05) nos parâmetros ecocardiográficos indicativos de hipovolemia entre os grupos. Não houve diferenças estatísticas (p = 0,083) nos parâmetros ecocardiográficos de contratilidade. Os resultados obtidos mostraram que os parâmetros ultrassonográficos da hipovolemia foram os mais associados no momento da hipotensão. Isso permite que o profissional seja orientado para o uso racional de drogas inotrópicas e reposição de volume.

SELECTION OF CITATIONS
SEARCH DETAIL